Product name: DC Power Supply Unit.
Power supply voltage: 24 VDC. 2A;
Total power consumption, 19.6w.
RUN output, No; Maintenance forecast monitor, No.
Standards: UC1, N, L, CE.
as well as the replacement.
maintenance.
AC power supply (25W).
dedicated bus. The most suitable Power Supply,
specifications and/or options.
Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 8outputs;
Maximum switching capacity, 12 to 24VDC, 2A;
Commons, 4 points, 1 common;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Current consumption: 5V, 0 OMRON CJ1W-PD022. 09A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications
CJ1W-PD022
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput.
Unit type: CJ1 Special I/O Units OMRON CJ1W-PD022.
Product name: Analog Output Unit.
I/O points: 8 outputs;
Signal range selection:
Set separately for each output.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V;
1/4,000 (Settable to 1/8,000) *2.
Conversion period: 1 ms/point,
(Settable to 250 μs/point)*2.
Accuracy at ambient temperature of 25°C:
±0.3% of F.S.
External connection: Removable terminal block OMRON CJ1W-PD022.
External power supply: 24 VDC +10% -15%, 140mA max.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.14A; 24V, 0.14*3.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals. Unit type: CJ1 Basic I/O Units.
name: B7A Interface Units.
Specifications: I/O points, 32 inputs/outputs;
External connection, Removable terminal block.
No. of words allocated: 4 words.
Current consumption: 5V, 0.07A; 24V, --.
Standards: UC1, CE.
IIt transmits 16 points of I/O signals per,
word with a pair of cables CJ1W-PD022.
Easy and minimized wiring effort,
The B7A Interface Unit and B7A Link Terminal,
can be used in the same way as a standard,
Basic I/O Unit and I/O Terminal withoutt,
any need to worry about communications CJ1W-PD022.
This characteristic reduces the wiring,
when using more than one relatively remote,
sensor or actuator.