Unit classification: CJ1 Special I/O Units.
(High Speed type).
Number of control axes : 2 axes.
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.27A; 24V, --.
Standards: UC1, CE.
Synchronization and Even Higher Speed.
and open-collector or line-driver outputs.
and the CJ1W-NC234/NC434 have line-driver outputs.
and direct drive motors.
Product name: DC Power Supply Unit.
Power supply voltage: 24 VDC. 2A;
24-VDC output capacity, 0.4A;
Total power consumption, 19.6w.
Options: 24-VDC service power supply, No;
RUN output, No; Maintenance forecast monitor, No.
Standards: UC1, N, L, CE.
Equipped with the RUN output for,
checking the operation status,
as well as the replacement OMRON CJ1W-NC234.
notification function for easy,
maintenance
CJ1W-NC234
Lineup of five models including the,
AC power supply (25W).
Stable power supply is available from the,
CJ-series CPU Unit to each I/O Units via the,
dedicated bus. The most suitable Power Supply,
Unit can be selected among various I/O ,
specifications and/or options. Unit classification: CJ1 Special I/O Units OMRON CJ1W-NC234.
Product name: Temperature Control Units.
Specifications; No. of loops: 2 loops,
heater burnout detection function;
Temperature sensor inputs: Thermocouple,
input (R, S, K, J, T, B, L);
Control outputs: Open collector,
PNP outputs (pulses).
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers OMRON CJ1W-NC234.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output. Unit classification: CJ1 Special I/O Units.
Product name: Process Analog Input Units,
(Isolated-type Resistance Thermometer Input Units).
Input points: 4 inputs.
Signal range selection: Common inputs.
Signal range: Resistance thermometer: Pt100, JPt100.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs.
Accuracy at ambient temperature of 25°C:
Accuracy: (±0.3% of PV or ±0.8°C,
whichever is larger) ±1 digit max.
External connection: Removable terminal block.
No. of unit numbers allocatedd: 1 CJ1W-NC234.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four inputt channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) CJ1W-NC234.
All inputs are isolated.