OMRON C200H-OD411 Product information and technical parameters:
Brand: OMRON
Name: Transistor Output Module
Model: C200H-OD411
Model: C200H-OD411.
No. of points: 8 pts.
Specifications: 1A, 12 to 48 VDC.

100 to 120/200 to 240 VAC (switchable), Wired.Connects Power Supply Adapter and SYSMAC NET Link Unit.
Included with C200H-APS02.Name: Temperature Sensor Module.
Model: C200H-TS101.
Temperature sensor: RTD (JPt 100 Ω.).
Input points: 4 points/Unit max. (1, 2, or 4 points can be selected).Name: Space Module OMRON C200H-OD411.
Model: C200H-BAT09.
Description: Replacement for memoryC200H CPU 100/200-240VAC C200H-CPU02-E C200H-OD411For Hand-held Programming Console.
2m.Model: C200H-PS221.
Supply voltage: 120/240VAC.Model: C200H-ID111.
No. of points: 64 pts.
Specifications: 12VDC.
Weight: 250g max.Model: C200H-OC225.
No. of points: 16 pts.
Specifications: 2A, 250VAC/24VDC(For resistive loads).Model: C200H-ID212.
No. of inputs: 16 pts OMRON C200H-OD411.
Input voltage: 24VDC, +10%/–15%.
Input current: 7mA, 24VDC.
Isolation: Photo-coupler.
Indica-tor: LED.
External connec-tions: Remove-able termi-nal blocks.
Inputs percom-mon: 16 pts.
Internal currentcon-sump-tion: 10mA max.C200H A Backplane I/O Mounting Bracket For 8 Slots C200H-ATTA3.Programmed using the Fuzzy Support Software. Up to 8 inputs and 4 outputs.Name: PC Link Module OMRON C200H-OD411.
Model: C200H-LK401.
Communications method: 2-conductor, half duplex.

PC Link Unit
Distributed control using the PC Link Unit.Connects SYSMAC LINK Unit, Controller Link Unit to CPU Unit.
For 1 Unit.Name: Host Link Module.
Model: C200H-LK101-PV1.
Communication ports: 1 fiber port.Model: C200H-B7A02.
I/O points: 32 output points.
Weight: 300g max.Model: C200H-OA222V.
No. of points: 12 pts.
Specifications: 0.3A, 250VAC.Model: C200HS-INT01.
Rated Input Voltage: 12 to 24 VDC +10%/–15%.
Input Impedance: 2 K.
Input Current: 10 mA typical (24 VDC).
ON Voltage: 10.2 VDC min.
OFF Voltage: 3.0 VDC max.
ON Response Time: 0.2 ms max.
OFF Response Time: 0.5 ms max.
No. of Circuits: Requireed when supplying backup power C200H-OD411.
For 2 Units.UM: 31.2K words.
DM: 6K words.
EM: 6Kx3 banks(18K) words.
Instruction processing time (basic instructions): 0.1 µ.s min.
No. of I/O points: 880 points.
Max. no.of con-necting Expansion I/OO Racks: 2 Racks C200H-OD411.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.