OMRON AGD-N52 Product information and technical parameters:
Brand: OMRON
Name: Leakage fire alarm
Model: AGD-N52
Type: collection type.
Enclosure: surface type.
30 years of best-selling products new upgrade in the reservation,
Based on the basic functions to achieve a compact.
The installation dimensions of the surface type remain unchanged, the volume ratio of the volume ratio of the square body is reduced,
Half. (excluding AGD-U2)
Built in digital filter to reduce the impact of high frequency interference, to achieve a higher accuracy,
Leakage monitoring.
The output point consists of 1c1a * monitoring circuit, an external signal based on contact,
Remote monitoring and alarm output of each monitoring circuit.
Cube embedded type also built-in buzzer. (except AGD-U2) alarm output,
Optional external buzzer.
After the upgrade of all products can choose automatic reset, manual reset.
(AGD-N5, AGD-NY5, AGD-N52)

Power ratings: 480 W.
Input voltage: 100 to 240 VAC.
Output voltage: 24 V.
Output current: 20 A Peak current 30 A (200 VAC).
Alarm output *2: Sinking/sourcing.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication OMRON AGD-N52.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that AGD-N52
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC OMRON AGD-N52.
(Not compliant with EC Directives and other safety standards.) Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 20 OMRON AGD-N52. 0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Specifications: For RS-232C port.
Type: RJ45/Dsub9Pin.
Length: 2 m.
Compact DC-DC UPS with a DIN rail for,
mounting, best suited for prevention of,
voltage drop and power failure in,
industrial-purpose computers.
(IPC)/controllers.
System reliability greatly improved because.
24VDC power supply is backed up for a certain.
pperiod of time in the event of voltage drop or power failure AGD-N52.
Compactness, weight reduction, and long battery life,
realized thanks to the adoption of a lithium-ion battery.
Push-in terminal block adopted for the power input and,
outputt I/F AGD-N52.
Shutdown in conjunction with the industrial,
purpose computer (IPC) or controller realized,
by the USB/RS-232C/I/O port installed in the UPS.


...More relevant models >>>>