Operating: Appearance, 60-dia. head Large Push-lock Turn-reset A22E-L;
Contact Configuration, 2NC (1NC + 1NC).
Color of cap: Red.
Install in 22-dia. or 25-dia. Panel Cutout.
Direct opening mechanism to open the circuit when the contact welds.
Safety lock mechanism prevents operating errors.
Easy mounting and removal of Switch Blocks using a lever.
multiple contacts).
standard feature.
Install using either round, or forked crimp terminals.
control box and switch are not easily separated.
Actuator: Plastic rod.
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC (Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available OMRON A22E-L-02. )
M12-connector models are also available, saving on labor and,
simplifying replacement
A22E-L-02
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Actuator: One-way roller arm lever (horizontal) OMRON A22E-L-02.
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability OMRON A22E-L-02.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Type of drive rod: roller plunger type.
Conduit size: single catheter type, M20.
Built in switch structure: slow motion (2NC).
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double coontact specifications (1NC/1NO, 2NC) A22E-L-02.
Forced open action structure.
The slow moving contact structure is adopted to ensure that the contact distance is 4mm.
Elevator and escalator can be used. Classification: Standard models.
Auxiliaryy outputs: Semiconductor outputs *1 A22E-L-02.
Cable length: 5 m.
Electronic Detection Mechanism for.
Better Stability in Non-contact Door.
Switch Operation.