Output: DPDT.
Lighting: LED.
Operating voltage: 12 VAC/VDC.
G: green, A: blue; PW: pure white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1.
Output: DPDT.
Lighting: Incandescent lamp.
Operating voltage: 24 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28 OMRON A16L-TYM-12D-2S. 5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads
A16L-TYM-12D-2S
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Actuator: Horizontal plunger.
Item: Basic.
Pretravel (PT): 2.8 mm max.
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches OMRON A16L-TYM-12D-2S.
Standard-feature gold-clad crossbar contacts provide high reliability.
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on approved models OMRON A16L-TYM-12D-2S. Output: DPDT.
Lighting: Non-lighted.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; Non-lighted.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Apppearance: High sound A16L-TYM-12D-2S.
w/jumper direction A *2: Intermittent (short).
w/jumper direction B *2(w/o jumper): Intermittent (long).
Supply voltage: 6 VAC/VDC.
Buzzer Unit Series with Cylindrical.
22-mm × 16-dia. Body.
Lineup includees standard-volume models (80 phons, constant) and,
high-volume models (70 to 95 phons, variable) A16L-TYM-12D-2S. Intermittent or,
continuous sound can be selected.