Appearance: Round/Flat type A22-F.
Output: SPST-NO.
Operation: Momentary operation (self-resetting).
Illumination color: R (red); Y (yellow); G (green);
W (white); A (blue); B (black).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature
E5AN-R3HHBT-W-N AC100-240
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Type: screw terminal type, micro load with cable.
Rated current; 0.1A AC125V.
Drive rod: plunger type.
Terminal: screw terminal with cable (right hand side).
Action indicator: no operation indicator.
Compared with D4E performance is stronger, in compliance with the requirements of high durability, high sealing.
Horizontal spring, with improved swing lever ratio of the built-in switch to provide a smooth action effect and a longer period of use.
Protection cover protects built-in switch from dust and oil pollution damage.
The plunger type combined with the solid sealing cover has longer service life.
One touch off connector wiring operation miscellaneous,
And reduce the downtime due to wiring and maintenance.
Gold Plated minimum load type is an ideal choice for electronic control.
Can provide terminal type plastic screw terminal system and terminal type plastic with operation indicator.
Certified by EN, UL, CSA and CCC (China Standard) standard.
Install the pitch and with the characteristics of D4E- - N and D4E. Time specification: Inverse type.
Current setting range: 2 to 8 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
E5AN-R3HHBT-W-N AC100-240 Operation manual / Instructions / Catalog download link: