Economical, Miniature Limit Switch.
Boasting Rigid Construction.
The Head, Box, and Cover mate with ridged surfaces to,
maintain strength.
A unique Head structure provides a large OT for smooth operation.
Easy-to-wire conduit opening design.
Ideal for application in printing machines, forming machines,
and light machines.
(High Switches with high sealing characteristics, such as WL or,
D4C Switches, in locations subject to oil, water, or precipitation
E53-CNQ03N2)
Models with grounding terminals conform to the CE marking.
Approved by CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)Conduit: JIS B 0202 G½.
Applicable cable: Cabtire cable (general purpose).
Inner diameter (D)of seal rubber: 11 mm.
External diameter of cable: Min, 9 mm; Max, 11 mm.
Applicable model: WL-N, WL, D4A-@N, D4B-@N, ZE, ZV, ZV2, XE, XV, XV2.
Connectors (SC Series).
Cabtire cables and flexible tubes with various diameters are used to,
connect machine tools and controllers with Limit Switches. To ensure,
the watertightness of the edges of the conduits, use an SC Connector,
that is suitable for the external diameter of cable and model of Limit Switch. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
E53-CNQ03N2 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E53-CNQ03N2&select=5