The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function E53-CNH03N2 INSTRUCTION Manual
E53-CNH03N2
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement E53-CNH03N2 INSTRUCTION Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Size: 48 x 96mm.
Control output 1: relay output (open) E53-CNH03N2 INSTRUCTION Manual.
Control output 2: relay output (off).
Power supply voltage: AC100 ~ 240V.
New highlight LCD panel, font larger, display more clearly integrated low power design,
Longer life performance stability,
Perfect function of proportional valve control special (some models have no potentiometer input virtual opening function)
E5AC-PR-800 white LCDPV display height to reach 25mm, greatly improve the visibility.
The main body is short, and the diameter is only 60mm.
50ms high speed sampling period. Size: 96 × 96 mm.
Control type: Position-proportional control (1 loop).
Control mode: Single-loop position-proportional control (See note.).
Outputs(control/transfer): Relay output (1 open, 1 close).
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, None; Serial communications, Yes.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using moodels with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4 E53-CNH03N2 Manual. 0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation) E53-CNH03N2 Manual.
DeviceNet Communications.
Data setting and monitoring can be performed without special programming.