Ratings: Standard load; 4 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Sealed roller plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material
E3S-AD68
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 6.4 dia.
Protective tubing length L: 35 cm.
Lead wire type: Heat resistive.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Type: 1a1b welding terminal.
Shape: rectangle.
Type: General load.
Action: instantaneous action (auto recovery).
With lamp: no light.
Operation Department color: black.
20mm long, with 12 round series
High brightness all one side light.
Because it is round, so easy to punch.
Miniaturization, operation feel good. High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control.
RS-485 communications to set manipulated variables and,
monitor load current.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,
and constant-current control.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified.
E3S-AD68 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E3S-AD68&select=5