OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E3S-AD22 Manual E3S-AD22 INSTRUCTION sheet

OMRON E3S-AD22 Manual E3S-AD22 INSTRUCTION sheet

Brand: OMRON
Product model: E3S-AD22
Name: photoelectric sensors
Sort: INSTRUCTION sheet
File language: English
File size: 0.24MB
Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function E3S-AD22 INSTRUCTION sheet E3S-AD22
Event input points: -.
Transfer output: -.
Communication: RS-485.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance E3S-AD22 INSTRUCTION sheet.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc E3S-AD22 INSTRUCTION sheet. , can be a key operation. Temperature range: -30.0 ~ 20.
Positive / inverse action: anti movement (heating).
Adjustment mode: OFF, ON action.
With the aid of microcomputer, the temperature control can be realized with high precision (0.1 degrees C).
Combined use of control equipment, adjustable sensitivity.
Attached to facilitate the energy saving operation of the set value conversion function, as well as ease of operation to stop the control function. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-422.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermoo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E3S-AD22 Manual.
Through the infrared port can be carried out from the frront of the communication E3S-AD22 Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Related products
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AD21
OMRON Built-in Amplifier Photoelectric Sensor E3S-AD21
Sensing method: Diffuse-reflective Sensors.
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AD73
OMRON Built-in Amplifier Photoelectric Sensor E3S-AD73
Sensing method: Diffuse-reflective Sensors.
OMRON
Identification sensor
E3S-VS1C4
OMRON Identification sensor E3S-VS1C4
Choose red, green light source of the 2 model
OMRON
PCB Sensors
E3S-LS3 Series
OMRON PCB Sensors E3S-LS3 Series
Reliale Detection Unaffected y PCB. Holes