Function name: 3 phase 200V.
Power: 7.5KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 3.4KG.
Dimension (w * h) 260mm *:140.
Outline dimension (deep):155mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication
E3S-2DB4 2M
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Power supply voltage: 24V DC±10%, Ripple (p-p): 10%.
Current consumption: 3.0A max.
Discharge voltage: ±7.5kV.
Discharge method: Variable DC.
Ionization time: 1 s.
Ion balance: ±10V max.
Amount of ozone generated: 0.01 ppm,
(Measured at a distance of 50 mm from air outlet).
Indicators: Power (Green), Fan running (Green), Cleaning (Yellow), Alarm (Red).
Main functions: Ion balance adjustment (Automatic and manual).
External output (for both cleaning and alarm outputs): Photo MOS relay output,
(NPN or PNP)Applied voltage: 30VDC max., load current: 100mA max.
Residual voltage: 1V max.
Discharge stop input: No-voltage contact input, ON: 0V short circuit,
OFF: Open (leakage current: 0.1mA max.).
Ambient temperature range: 0 to 50˚C (No icing or dewing).
Ambient humidity range: 35% to 65% (No icing or dewing).
Weight (Packaged): Approx. 2 kg (Approx. 3 kg).
Material: Body:Aluminum, ABS Electrode needle: Tungsten.
Accessories: Instruction sheet, I/O connector, Stand, Streamer.
This ionizer series is designed to go anywhere.
All models are easily installed on narrow,
workbenches or in high positions where earlier,
models presented installation issues. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
E3S-2DB4 2M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E3S-2DB4 2M&select=5