Power supply voltage: 12 to 24 VDC.
Output configuration: Open-collector output (PNP).
Output code: Gray.
Resolution (divisions): 256, 360, 720, 1,024.
Connection method: Pre-wired Model (1 m).
Rugged Rotary Encoder.
Absolute model.
External diameter of 50 mm.
Resolution of up to 1,024 (10-bit).
IP65 (improved oil-proof protection with sealed bearings).
Optimum angle control possible in combination with PLC or,
Cam Positioner
E3S-2B4 5M Size: 96 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2: relay output.
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 1 points.
Communication: -.
Event input: 4 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Ideal for Controlling Pumps and Production.
Lines with Six or Twelve Stepping Circuits.
Built-in relays switch 2 A at 250 VAC or 30 VDC.
Initialization of stepping with reset input.
Uses memory that stores setting status for 10 days without.
power. All internal contacts are released when no power is supplied.
Detects an internal element malfunction caused by external.
noise, indicates the malfunction with an alarm indicator, and,
turns the relay alarm output ON. (An internal relay malfunction,
or internal relay contact weld cannot be detected.).
With safety-design terminals which prevent electric shock accidents.
With easy-to-see indicators which display the stepping status.