I/O bits: 5, 120 (Expan-sion Racks: 7).
Program capacity: 30K steps.
Data memory capacity: 64K words (DM: 32K words, EM: 32K words ×1 banks).Type: 1A contact type.
Shape: square.
Terminal shape: solder terminal.
Action: instantaneous.
Display mode: LED display.
Operation Department color: red.
Large capacity compact type push button switch.
Can also be used as a power switch with a large capacity cut
1VAP2-6
Can be switched from micro load (minimum applicable load 1mA DC5V) to large capacity load. Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: Externally attached heat sinks.
Applicable load: 15 A, 100 to 240 VAC.
Number of pole: 3.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN Track Mounting.
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification). Model: C500-BC061(3G2A5-BC061).
6 slots(5 linkable slots).
Cable specifications: Oil-resistant Polyurethane Cable.
Cable length L: 2 m.
Cable outer diameter: 6 mm.
Straight Connectors.
Minimum order: 5.
UL: --.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved. New 96 x 96-mm and 48 x 96-mm Basic Temperature Controllers with,
Enhanced Functions and Performance.
Improved Indication Accuracy and,
Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%).
Pt input: ±0.2% of PV (previous models: ±0.5%).
Analog input: ±0.2% FS (previous models: ±0.5%).
A PV/SV-status display function can be set to automatically,
alternate between displaying the status of the Temperature,
Controller (auto/manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Three-level display that simultaneously displays the PV, SV, and MV.
One-touch operation with PF Key that can be assigned to,
auto/manual, RUN/STOP, or other functions.
1VAP2-6 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=1VAP2-6&select=5