Output voltage: 5 V.
Output current: 5 A.
Screw terminal Model: Without Bus Line (See note 2.).
Block-type Switch Mode Power Supply That.
Mounts to DIN Rail.
One model covers 30 to 120 W (12-V models).
One model covers 60 to 240 W (24-V models).
Easy creation of multi-power supply configurations with different,
output power supplies connected together (5-V, 12-V, and 24-Vmodels).
Improve power supply system reliability by creating N+1 redun,
dant systems (12-V and 24-V models)
C500-ZL3DV1
RoHS-compliant.
Input conditions: 80 to 370 VDC supported for DC input too,
(EC Directives and safety standards are not applicable.)
Operating temperatures to –20°C (24-V models). Product name: CS1 Expansion Backplanes.
Specifications: For both CS/C200H-series,
Units; 10 slots.
Mountable configuration units:
Basic I/O Units, CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, Yes;
C200H Group-2 High density I/O Unit, Yes.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, Yes.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
Current consumption: 5V system, 0.23A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Installation method: surface mount, embedded mounting (common).
Action: power on delay action.
Action mode / reset mode: time limit action / auto reset.
Set lock mechanism.
External connection mode: 8P socket.
Time limit contact: 2c.
Instantaneous contact: No.
1 timer to achieve AC/DC free power,
8 action functions 0.1 seconds to 9990 hours.
Through time display windows wide, eye-catching.
Free power mode using AC24 ~ 240V/DC12 ~ 240V.
And the DC specification does not have to specify the polarity.
8 action functions can be selected by the action function switch.
Combined operation of time setting switch and time unit switch,
Achieve 0.1 seconds to 9990 hours rangeOntology: program type.
Size: 48 x 96mm.
Type: basic type (1 input).
Control mode: standard control, heating and cooling control.
Output (control / transfer) points: 2 points (pulse + pulse / current).
Output (SUB) points: 4 points.
Event entry point: 2.
Serial communication: RS-485.
New high speed, high precision digital regulator (Cheng Xuxing)!
Can be set up to 32 kinds of procedures.
1 units can be coordinated to run up to 4 channels.
High speed acquisition of 50ms.
With CX-Thermo on the computer easily set.
C500-ZL3DV1 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=C500-ZL3DV1&select=5