OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON C500-RM001-EV1 Manual C500-RM001-EV1 User's Manual

OMRON C500-RM001-EV1 Manual C500-RM001-EV1 User's Manual

Brand: OMRON
Product model: C500-RM001-EV1
Name: Safety Light Curtain
Sort: User's Manual
File language: English
File size: 1.04MB
Control method: Semiclosed loop with automatic trapezoid or S-curve acceleration/deceleration.
Control output signals: Analog.
Controlled axes: 2 axes max.C500-RT SYSMAC BUS Remote I/O Master Slave Wired C500-RT002-PV1.
APF/PCF.With two optical connectorsModel: CPM2C-32CDT1M-D. CPU Unit: Units with 32 I/O points C500-RM001-EV1 User's Manual.
2 MIL connectors.
Inputs: 16 inputs.
Outputs: 16 outputs C500-RM001-EV1
Input type: 24 VDC.
Output type: sourcing transistor.
Internal clock: --.Name: External Connector.
Model: C500-CE403.
Specifications: Pressure welded terminal; 40p.Unit type: CS1 Special I/O Units.
Product name: Power Transducer Input Unit.
Input points : 8 inputs.
Signal range: 0 to 1 mA, ±1 mA.
Conversion speed (resolution):
200ms/8 inputs C500-RM001-EV1 User's Manual.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.08A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value C500-RM001-EV1 User's Manual.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools. 2 platinum resistance thermometer inputsUnit classification: CJ1 CPU Bus Unit.
Specifications:Equipped with Master,
and Slave functionality.
CControls for up to 32,000 points per Master C500-RM001-EV1 Manual.
Communications:Remote I/O Communications,
Master (fixed allocations or user-set,
allocations) Remote I/O Communications,
Slave (fixed allocations or user-set,
allocations) Messsage communica29A; 24V,-- C500-RM001-EV1 Manual.
Smallest in the Industry!
A DeviceNet Unit for the,
CJ Series that Boasts Industry-leading,
Performance and Functions.
Related products
OMRON
SYSBUS Remote I/O Unit
C500-RM001-V1(3G2A5-RM001-V1)
OMRON SYSBUS Remote I/O Unit C500-RM001-V1(3G2A5-RM001-V1)
C500-RM SYSMAC BUS Remote I/O Master Wired C5
OMRON
SYSBUS Remote I/O Unit
C500-RM201(3G2A5-RM201)
OMRON SYSBUS Remote I/O Unit C500-RM201(3G2A5-RM201)
C500-RM SYSMAC BUS Remote I/O Master Wired C5
OMRON
SYSBUS Remote I/O Unit
C500-RM001-PV1(3G2A5-RM001-PEV1)
OMRON SYSBUS Remote I/O Unit C500-RM001-PV1(3G2A5-RM001-PEV1)
C500-RM SYSMAC BUS Remote I/O Master Wired C5