Terminal type: Exposed-lead Models.
Protective tubing diameter D: 6.4 dia.
Protective tubing length L: 35cm.
Lead wire type: Heat resistive.
Lead wire length M: 8m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers
PY14-Y2
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Cable length L: 3.0 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Power supply voltage: 12 VDC.
Output configuration: Voltage output.
Output code: Binary.
Resolution (divisions): 256.
Connection method: Pre-wired Model (1 m).
Rugged Rotary Encoder.
Absolute model.
External diameter of 50 mm.
Resolution of up to 1,024 (10-bit).
IP65 (improved oil-proof protection with sealed bearings).
Optimum angle control possible in combination with PLC or,
Cam Positioner. Lock method: Solenoid lock.
Conduit size: PG13.5.
Voltage for solenoid: 24 VDC.
Without indicator 2NC+ 1NC (Slow-action).
Release Protective Cover Locks Using.
Controller Signals or Pushbutton.
Switches after the Cutting Tool Stops.
Moving Due to Inertia.
A mechanical lock is applied automatically when the Operation.
Key is inserted. A high level of safety is achieved using a,
mechanism where the lock is only released when voltage is,
applied to the solenoid.
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL, CSA and CCC standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened.
Direct opening mechanism that is EN-certified is indicated by,
on the Switch.
Auxiliary release key ensures easy maintenance and unlocks the,
door in the case of a power failure.
Tough aluminum die-cast body incorporating a switch box with,
degree of protection satisfying IP67, UL, and CSA TYPE6P, 13.
Equipped with a horizontal and vertical conduit opening.
Models incorporating easy-to-see indicators for monitoring and,
those using an adjustable Operation Key for a swinging door are available.
The mounting direction of the head can be changed,
to allow the Operation Key to be inserted from four directions.
PY14-Y2 Operation manual / Instructions / Catalog download link: