OMRON K3HB-XVA-T11 AC100-240 Pirce

Brand: OMRON
Country: JAPAN
Name: Voltage and current panel meter
Price: 0
OMRON K3HB-XVA-T11 AC100-240
Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function K3HB-XVA-T11 AC100-240
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Unit type: CS1 Basic I/O Units.
Product name: AC Input Unit.
Specifications: 100 to 120 VAC,
16 inputs 100 to 120 VDC, 16 inputs.
Mountable Racks: CPU Rack, CS1W-BC,
@@3,YES, @@2, YES;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,@@3,YES,
@@2, YES; CS1 Long distance Expansion Rack,
Yes; SYSMAC BUS Slave Rack, No.
Words required: (I/O bits: CIO 0000 to CIO 0319), 1 word.
Current consumption: 5V system, 0.11A;
26 V system, --.
Standards: UC1, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 2 loops,
heater burnout detection function;
Temperature sensor inputs: Thermocouple,
input (R, S, K, J, T, B, L);
Control outputs: Open collector,
NPN outputs (pulses).
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output.
K3HB-XVA-T11 AC100-240 Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=K3HB-XVA-T11 AC100-240&select=5