Measuring voltage: 20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC.
Supply voltage: 24 VAC/DC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 6 A at 250 VAC (resistive load) K3HB-XVA-T11 Communications Manual.
Output relay can be switched between normally open and normally closed
K3HB-XVA-T11
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Measuring voltage: 6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC K3HB-XVA-T11 Communications Manual.
Supply voltage: 24 VAC/DC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and,
undervoltages.
Manual resetting and automatically resetting supported by one Relay.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load) K3HB-XVA-T11 Communications Manual.
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Functions: Phase sequence and phase loss monitoring.
Rated input voltage: 200 to 500 VAC.
Three-phase Phase-sequence Phase-loss.
Relay Using Voltage Detection Method.
Fixed phase Asymmetry monitoring.
Prevents reverse motor rotation due to incorrect wiring.
Distinguishes between positive phases, reversed phases, and phase,
loss when power is turned ON.
Voltage detection method enables application for any load current.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output status can be monitored using LED indicator. Static type reverse electric relay K2WR type.
Reverse power relay for household and marine generator.
A high precision power detection can be performed by the analog time division multiplier.
Through the rated voltage of the switch, adjust the current simulation of variable,,
Can correspond to the rated value of all generators K3HB-XVA-T11 Manual.
Due to the instant start in contact, the response difference is minimal,
Position detection with high accuracy. Sharing with voltage input, no need to control the power suppply K3HB-XVA-T11 Manual.
Because it is static, so the anti vibration impact ability, action stability.
Equipped with easy to manage and maintain the boot display with LED.