Input voltage: 24 VDC.
Output voltage: 24 VDC.
Output current/capacity: 15 A/360 W.
Compact DC-DC UPS with a DIN rail for,
mounting, best suited for prevention of,
voltage drop and power failure in,
industrial-purpose computers.
(IPC)/controllers.
System reliability greatly improved because.
24VDC power supply is backed up for a certain SDV-FL3 User's Manual.
period of time in the event of voltage drop or power failure
SDV-FL3
Compactness, weight reduction, and long battery life,
realized thanks to the adoption of a lithium-ion battery.
Push-in terminal block adopted for the power input and,
output I/F.
Shutdown in conjunction with the industrial,
purpose computer (IPC) or controller realized,
by the USB/RS-232C/I/O port installed in the UPS SDV-FL3 User's Manual. Power ratings: 30 W.
Output voltage: 12 V.
Output current: 2.5 A.
Boost current: --.
Newly Released High-capacity 240-W Models in S8EX-series Lineup.
Rated Output of 300 W for 200 VAC.
From 170 to 264 VAC.
New 240-W Models.
Lineup of models with 24-, 36-, and 48-VDC output.
voltages.
15-W, 35-W, 50-W, 100-W, and 150-W Models.
Lineup of models with from 5 to 48-VDC output SDV-FL3 User's Manual.
voltages.
All Models.
Approved standards:
UL60950-1, cUR CSA C22.2 No. 60950-1, EN 50178,
and EN 60950-1.
Lineup includes open-frame models, models with.
chassis, and models with chassis and covers.
Wide-range power supply: 100 to 240 VAC.
Complies with harmonic current standard in EN.
61000-3-2 (50-W to 240-W models).
The top class in industry for compact size.
Boost current output (some models excluded). Type: open type.
Structure: bottom mounting type.
Capacity: 150W.
Output voltage: 5V.
Output current: 27A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
SSupport finger touch protection to prevent electric shock SDV-FL3 Manual.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whhen the fan is replaced by the customer SDV-FL3 Manual. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)