OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON SAO-QS5N Manual SAO-QS5N Installation and Operating Manual

OMRON SAO-QS5N Manual SAO-QS5N Installation and Operating Manual

Brand: OMRON
Product model: SAO-QS5N
Name: Smart Camera
Sort: Installation and Operating Manual
File language: English
File size: 0.25MB
Control power supply voltage: 200/220 VAC.
Input: DC or AC (selectable), Input voltage range, 10 to 300 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) SAO-QS5N Installation and Operating Manual.
Detect three-phase AC current for under and/or overcur,
rent using current converter SAO-QS5N
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F) SAO-QS5N Installation and Operating Manual.
LED operation indicator.
UL/CSA approval (SDV-F@). Power Supply: Model, S82J; Capacity, 100 or 150 W.
Easy-to-use DIN Rail Mounting Bracket for,
Power Supplies.
Mounts to the PFP-100N and PFP-100N2 DIN Rails.
Supports models S82J (100, 150-W models). Power ratings: 240 W.
Output voltage: 48 V.
Output current: 5 A (100 VAC) 6 SAO-QS5N Installation and Operating Manual. 3 A (200 VAC).
Boost current: 10 A.
Newly Released High-capacity 240-W Models in S8EX-series Lineup.
Rated Output of 300 W for 200 VAC.
From 170 to 264 VAC.
New 240-W Models.
Lineup of models with 24-, 36-, and 48-VDC output.
voltages.
15-W, 35-W, 50-W, 100-W, and 150-W Models.
Lineup of models with from 5 to 48-VDC output.
voltages.
All Models.
Approved standards:
UL60950-1, cUR CSA C22.2 No. 60950-1, EN 50178,
and EN 60950-1.
Lineup includes open-frame models, models with.
chassis, and models with chassis and covers.
Wide-range power supply: 100 to 240 VAC.
Complies with harmonic current standard in EN.
61000-3-2 (50-W to 240-W models).
The top class in industry for compact size.
Boost current output (some models excluded). Control power supply voltage: 48 VDC.
Input: DC, Input voltage range, 10 to 300 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Avvailable in 7 supply voltage configurations SAO-QS5N Manual.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrse current detection SAO-QS5N Manual.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).
Related products
OMRON
Current Sensor
SAO-Q2N
OMRON Current Sensor SAO-Q2N
Terminal/mounting: Plug-in/DIN rail via socke
OMRON
Current Sensor
SAO-Q7N
OMRON Current Sensor SAO-Q7N
Terminal/mounting: Plug-in/DIN rail via socke
OMRON
Current Sensor
SAO-SU2N
OMRON Current Sensor SAO-SU2N
Terminal/mounting: Plug-in/DIN rail via socke
OMRON
Current sensor (Dan Xiangyong)
SAO-RS2N
OMRON Current sensor (Dan Xiangyong) SAO-RS2N
Appearance: insert type. Control supply volta