Ideal for Monitoring 3-phase Power.
Supplies for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor overvoltages, undervoltages, phase sequence,
and phase loss for three-phase 3-wire or 4-wire power,
supplies with just one Unit.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply KM50-C1-FLK Communications Manual.
Two SPDT output relays, 5 A at 250 VAC (resistive load) KM50-C1-FLK
Output overvoltages and undervoltages using separate relays.
World-wide power specifications supported by one Unit (switchable).
Output status can be monitored using LED indicator. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase) KM50-C1-FLK Communications Manual.
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control KM50-C1-FLK Communications Manual.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Time specification: Inverse type.
Current setting range: 2 to 8 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicatedd from the start of operation KM50-C1-FLK Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions KM50-C1-FLK Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Smart Power Monitor
KM50-E1-FLK
OMRON Smart Power Monitor KM50-E1-FLK
Applicale circuits: Single-phase, 2-wire: 10
OMRON
Programmed temperature controller
E5CN-HTQ2H01-FLK
OMRON Programmed temperature controller E5CN-HTQ2H01-FLK
Size: 48 48mm, terminal type. Category: con
OMRON
Programmed temperature controller
E5CN-HTR2H01-FLK
OMRON Programmed temperature controller E5CN-HTR2H01-FLK
Size: 48 48mm, terminal type. Category: con
OMRON
High performance temperature controller
E5CN-HV201-FLK
OMRON High performance temperature controller E5CN-HV201-FLK
Size: 48 x 48mm. Body: terminal type. Categor