OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E5CN-HTR2H01-FLK Communications Functions MANUAL E5CN-HTR2H01-FLK User's Manual

OMRON E5CN-HTR2H01-FLK Communications Functions MANUAL E5CN-HTR2H01-FLK User's Manual

Brand: OMRON
Product model: E5CN-HTR2H01-FLK
Name: Temperature Controller
Sort: User's Manual (Communications Functions)
File language: English
File size: 0.55MB
Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: built-in SSR output.
Control output 2: built-in SSR output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater E5CN-HTR2H01-FLK User's Manual.
Event entry point: 2 E5CN-HTR2H01-FLK
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved E5CN-HTR2H01-FLK User's Manual.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5CN-HTR2H01-FLK User's Manual.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. Terminal type: Enclosed-terminal Models.
Protective tubing length L: 20cm.
Protective tubing diameter D (mm): 3.2 dia.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Terminal type: Enclosed-terminal Models.
Protective tubing length L: 50cm.
Protective tubing diameter D (mm): 8 dia.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5CN-HTR2H01-FLK Communications Functions MANUAL.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5CN-HTR2H01-FLK Communications Functions MANUAL.
Related products
OMRON
Programmed temperature controller
E5CN-HTR2H03-FLK
OMRON Programmed temperature controller E5CN-HTR2H03-FLK
Size: 48 48mm, terminal type. Category: con
OMRON
Programmed temperature controller
E5CN-HTR2H01D-FLK
OMRON Programmed temperature controller E5CN-HTR2H01D-FLK
Size: 48 48mm, terminal type. Type: control
OMRON
High performance temperature controller
E5CN-HQ2H01-FLK
OMRON High performance temperature controller E5CN-HQ2H01-FLK
Size: 48 x 48mm. Body: terminal type. Categor
OMRON
High performance temperature controller
E5CN-HR2H01-FLK
OMRON High performance temperature controller E5CN-HR2H01-FLK
Size: 48 x 48mm. Body: terminal type. Categor