OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON K8AB-PM2-TE Manual K8AB-PM2-TE User's Manual

OMRON K8AB-PM2-TE Manual K8AB-PM2-TE User's Manual

Brand: OMRON
Product model: K8AB-PM2-TE
Name: Digital Temperature Controllers
Sort: User's Manual
File language: English
File size: 0.05MB
Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element K8AB-PM2-TE User's Manual.
Burnout Detector compatible with a,
wide-range of heater control methods K8AB-PM2-TE
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance K8AB-PM2-TE User's Manual.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase) K8AB-PM2-TE User's Manual.
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicatedd from the start of operation K8AB-PM2-TE Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K8AB-PM2-TE Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Three-phase Asymmetry
K8AB-PA1
OMRON Three-phase Asymmetry K8AB-PA1
Rated input See note 2.: 3-phase 3-wire mod
OMRON
Single-phase Current Relay
K8AB-AS1 AC200/230V
OMRON Single-phase Current Relay K8AB-AS1 AC200/230V
Measuring current: 2 to 20 mA AC/DC, 10 to 10
OMRON
Single-phase Current Relay
K8AB-AS3 AC/DC24V
OMRON Single-phase Current Relay K8AB-AS3 AC/DC24V
Measuring current: 10 to 100 A AC, 20 to 200
OMRON
Temperature Monitoring Relay
K8AB-TH12S AC100-240
OMRON Temperature Monitoring Relay K8AB-TH12S AC100-240
Size: K8AB-TH 22.5 × 90 × 100 mm. Supply vol