File size: 2.54MB
Setting range: 10 to 100 A AC, 20 to 200 A AC.
Power supply voltage: 100 to 240 VAC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents and undercurrents simultaneously.
Separate settings and outputs supported for overcurrents and undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A) K3MA-F-A2 User's Manual K3MA-F-A2
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
Two sets of SPDT output contacts, 5 A at 250 VAC (resistive load).
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Product: Replacement Dischargers (set of 5) K3MA-F-A2 User's Manual.
Wide Range of Nozzles for Optimal.
Ionization.
A wide range of nozzle variations.
High-frequency AC method with excellent ion balance. Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase) K3MA-F-A2 User's Manual.
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Size: K8AB-TH 22.5 × 90 × 100 mm.
Supply voltage: 24 VAC/VDC.
Type: Temperature input.
Number of outputs: 1 (relay).
Input type: Thermocouple/Pt100.
Setting unit (setting range): Unit: 1°C/°F (0 to 399°C/°F).
Compact and Slim Relay Ideal for.
Temperature Alarms and Monittoring K3MA-F-A2 Manual.
Excessive temperature increases can be prevented and,
abnormal temperatures can be monitored.
Temperature monitoring in slim design with a width of just 22.5 mm.
Simple function settings using DIP switch.
Universal-inpput support for thermocouple or Pt100 sensor input K3MA-F-A2 Manual.
Selectable output relay: Non-fail safe/fail safe.
Alarm status identification with LED indicator.
Related products
OMRON
Frequency/Rate Meter
K3MA-F-A2 AC100-240V
OMRON Frequency/Rate Meter K3MA-F-A2 AC100-240V
Input type: Rotary pulse. Supply voltage: 10
OMRON
Temperature Meter
K3MA-L Series
OMRON Temperature Meter K3MA-L Series
Highly Visile LCD Display with 2-color Red
OMRON
Process Meter
K3MA-J-A2 AC/DC24V
OMRON Process Meter K3MA-J-A2 AC/DC24V
Input type: DC voltage/current. Supply volta
OMRON
Temperature Meter
K3MA-L-C AC/DC24V
OMRON Temperature Meter K3MA-L-C AC/DC24V
Input type: Platinum-resistance thermometer o