OMRON
Home >> Download >> OMRON >> Catalog Download >> OMRON K3MA-J-A2 AC100-240V datasheet PDF catalog K3MA-J-A2 AC100-240V PDF datasheet

OMRON K3MA-J-A2 AC100-240V datasheet PDF catalog K3MA-J-A2 AC100-240V PDF datasheet

Brand: OMRON
Product model: K3MA-J-A2 AC100-240V
Name: Process Meter
Sort: PDF datasheet
File language: English
File size: 1.44MB
Power supply voltage: 100 to 240 VAC.
Ideal for Liquid Level Control in.
Industrial Facilities and Equipment.
Self-holding circuit implemented with circuit processing that is,
not depending on external wiring.
Switch between water supply and discharge with a DIP switch setting.
Sensitivity adjustment of operating resistance from 10 k to 100,
kΩ for application to a wide range of liquids K3MA-J-A2 AC100-240V PDF datasheet K3MA-J-A2 AC100-240V
Prevents chattering of relay contacts that occurs with ripples.
Easy wiring with ferrules.
Use 2 × 2.5 mm2 solid wire or 2 × 1.5 mm2 ferrules.
Applicable as a floatless switch. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase) K3MA-J-A2 AC100-240V PDF datasheet.
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control K3MA-J-A2 AC100-240V PDF datasheet.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operration K3MA-J-A2 AC100-240V datasheet PDF catalog.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3MA-J-A2 AC100-240V datasheet PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Temperature Meter
K3MA-L AC100-240V
OMRON Temperature Meter K3MA-L AC100-240V
Input type: Platinum-resistance thermometer o
OMRON
Process Meter
K3MA-J-A2 AC/DC24V
OMRON Process Meter K3MA-J-A2 AC/DC24V
Input type: DC voltage/current. Supply volta
OMRON
Temperature Meter
K3MA-L-C AC100-240V
OMRON Temperature Meter K3MA-L-C AC100-240V
Input type: Platinum-resistance thermometer o
OMRON
Frequency/Rate Meter
K3MA-F-A2 AC100-240V
OMRON Frequency/Rate Meter K3MA-F-A2 AC100-240V
Input type: Rotary pulse. Supply voltage: 10