Input type: DC voltage input type.
Output type: relay contact; 1c HH; PASS, H, L, LL: each 1a.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth K3HB-XVD-FLK1AT11 User's Manual.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table
K3HB-XVD-FLK1AT11
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type K3HB-XVD-FLK1AT11 User's Manual. Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K3HB-XVD-FLK1AT11 User's Manual.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Condensed in the control cabinet for all power monitoring function.
Intelligent electric power monitor conforming to the international standard.
The design, installation, wiring, assembly and other issues can be resolved by the 1.
Small and optional measurement of multiple loops. Control supply voltage: 110/220 VAC; Without voltage fluctuation compensation.
Operating current: 0.5 to 1 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned ellement even if one heater el,
ement among several heater elements has been burned out K3HB-XVD-FLK1AT11 Manual.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with booth single-phase and three-phase heaters K3HB-XVD-FLK1AT11 Manual.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.