Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K3HB-XVA-1 Communications Manual.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
K3HB-XVA-1
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-XVA-1 Communications Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET, COMPENSATION) is equipped with K3HB-XVA-1 Communications Manual.
External power supply DC12V80mA.
BCD+ transistor: -; NPN open collector (5 digit output +OUT5, OUT4, OUT3, OUT2, OUT1).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speed pulse.
Measuring, increasing or decreasing pulse meter.
Action determine the color, can switch the green / Red 2 kinds of color display.
The best choice of rotating encoder and all kinds of ON/OFF pulse signal at high speed,
Cumulative pulse input is 50kHz, phase difference pulse isTime specification: Inverse type.
Current setting range: 2 to 8 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicateed from the start of operation K3HB-XVA-1 Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-XVA-1 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.