OMRON K3HB-XVA-1 Manual K3HB-XVA-1 Communications Manual

Brand: OMRON
Product model: K3HB-XVA-1
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 2.07MB
Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K3HB-XVA-1 Communications Manual.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K3HB-XVA-1
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-XVA-1 Communications Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET, COMPENSATION) is equipped with K3HB-XVA-1 Communications Manual.
External power supply DC12V80mA.
BCD+ transistor: -; NPN open collector (5 digit output +OUT5, OUT4, OUT3, OUT2, OUT1).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speed pulse.
Measuring, increasing or decreasing pulse meter.
Action determine the color, can switch the green / Red 2 kinds of color display.
The best choice of rotating encoder and all kinds of ON/OFF pulse signal at high speed,
Cumulative pulse input is 50kHz, phase difference pulse isTime specification: Inverse type.
Current setting range: 2 to 8 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicateed from the start of operation K3HB-XVA-1 Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-XVA-1 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Voltage and current panel meter
K3HB-XVD-ABCD1 AC/DC24
OMRON Voltage and current panel meter K3HB-XVD-ABCD1 AC/DC24
Input type: DC voltage input type. Output ty
OMRON
Voltage and current panel meter
K3HB-XAA-DRT1 AC100-240
OMRON Voltage and current panel meter K3HB-XAA-DRT1 AC100-240
Type of input: AC current input. Output type
OMRON
Time interval table
K3HB-PPB-FLK3AT11 AC/DC24V
OMRON Time interval table K3HB-PPB-FLK3AT11 AC/DC24V
Input type: PNP input type. Event input term
OMRON
Load sensor, mV instrument
K3HB-VLC-CPEC21 AC/DC24
OMRON Load sensor, mV instrument K3HB-VLC-CPEC21 AC/DC24
Category: external supply 100mA DC5V type. I