OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON K3HB-VLC-CPEC21 Manual K3HB-VLC-CPEC21 User's Manual

OMRON K3HB-VLC-CPEC21 Manual K3HB-VLC-CPEC21 User's Manual

Brand: OMRON
Product model: K3HB-VLC-CPEC21
Name: Digital Temperature Controllers
Sort: User's Manual
File language: English
File size: 2.28MB
Product: 500-mm Conductive Urethane Tube.
Wide Range of Nozzles for Optimal.
Ionization.
A wide range of nozzle variations.
High-frequency AC method with excellent ion balance. Input type: DC current input.
Output type: relay contact; 1c HH; PASS, H, L, LL: each 1a.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with K3HB-VLC-CPEC21 User's Manual.
External supply 80mA DC12V K3HB-VLC-CPEC21
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend K3HB-VLC-CPEC21 User's Manual.
External event input can be applied to a variety of measurement and identification situations.
DeviceNet type systemInput type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Relay contact: H; PASS1c, L, each 1c K3HB-VLC-CPEC21 User's Manual.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, the maximum can be measured from 10ms to 320Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operationn time,
is indicated from the start of operation K3HB-VLC-CPEC21 Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeency, basic,
frequency, and load conditions K3HB-VLC-CPEC21 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-CPEC21 AC/DC24
OMRON Load sensor, mV instrument K3HB-VLC-CPEC21 AC/DC24
Category: external supply 100mA DC5V type. I
OMRON
Load sensor, mV instrument
K3HB-VLC-L1BT11 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-L1BT11 AC100-240
Category: external supply 100mA DC10V. Input
OMRON
Load sensor, mV instrument
K3HB-VLC-L2BT11 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-L2BT11 AC100-240
Category: external supply 100mA DC10V. Input
OMRON
Load sensor, mV instrument
K3HB-VLC-CPEC11 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-CPEC11 AC100-240
Category: external supply 100mA DC5V type. I