OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON K3HB-XAD-FLK1AT11 Manual K3HB-XAD-FLK1AT11 User's Manual

OMRON K3HB-XAD-FLK1AT11 Manual K3HB-XAD-FLK1AT11 User's Manual

Brand: OMRON
Product model: K3HB-XAD-FLK1AT11
Name: Digital Temperature Controllers
Sort: User's Manual
File language: English
File size: 2.28MB
Product: 500-mm Silicone Tube.
Wide Range of Nozzles for Optimal.
Ionization.
A wide range of nozzle variations.
High-frequency AC method with excellent ion balance. Control supply voltage: 110 VAC; With voltage fluctuation compensation.
Operating current: 4 to 10 A.
Accurate Detection of Heater Element K3HB-XAD-FLK1AT11 User's Manual.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal K3HB-XAD-FLK1AT11
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters K3HB-XAD-FLK1AT11 User's Manual.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Type: Medium-sensitivity models.
Sensed current: 100 mA/200 mA (switchable).
Type: Delayed models.
Operating time: 0.3/0.8 s (switchable).
Economical, Compact, High-performance,
DIN 48 × 48-mm Ground Fault Relay for Low,
Voltages K3HB-XAD-FLK1AT11 User's Manual.
Performs continuous monitoring and detection of ground faults,
in low-voltage circuits due to the deterioration of insulation in,
electrical devices.
Higher reliability ensured with improved resistance to high-fre,
quency noise when used for inverter loads.
Ground Fault Relays and through-type ZCTs (zero-phase current,
transformers) are mutually compatible.
The through-type ZCTs are equipped with test terminals,
allowing operation tests for Ground Fault Relays to be performed withease. Rated input voltage: 3-phase 3-wire mode, 380, 400, 415, or 480 VAC.
Ideal for 3-phase Voltage Asymmetry.
Monitoring for Industriall Facilities and Equipment K3HB-XAD-FLK1AT11 Manual.
Greater resistance to inverter noise.
Monitor voltage asymmetry, phase sequence, and phase loss in three,
phase three-wire circuits with one unit.
One SPDT output relay, 5 A at 250 VAC (resisstive load) K3HB-XAD-FLK1AT11 Manual.
World-wide power specifications supported by one unit.
(Set with a rotary switch.).
Relay status can be monitored using LED indicator.
Related products