Type of input: platinum resistance / thermocouple input.
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with.
Linearity: voltage; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24.
Temperature indicator and measurement of various processes K3HB-RPB Communications Manual.
Action determine the color, can switch the green / Red 2 kinds of color display
K3HB-RPB
High speed sampling of 50 /s (20ms).
0.01 degree: platinum temperature resistance body Pt100 high resolution.
Thermocouple sensor (full range) to support the resolution of 0.1.
The temperature input compensation can be easily set by 2 points.
DevicMeasuring current: 10 to 100 A AC, 20 to 200 A (See note K3HB-RPB Communications Manual. ).
Supply voltage: 200-230 VAC.
Ideal for current monitoring for,
industrial facilities and equipment.
Monitor for overcurrents or undercurrents.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and,
normally closed K3HB-RPB Communications Manual.
Process control signal (4 to 20 mA) and commercial CT input,
(0 to 1 A or 0 to 5 A) supported.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Setting range: 10 to 100 A AC, 20 to 200 A AC.
Power supply voltage: 24 VAC/DC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents or undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A).
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 5 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Control supply voltage: 220 VAC; With voltage fluctuation compensation.
Operating current: 16 to 40 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out K3HB-RPB Manual.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with booth single-phase and three-phase heaters K3HB-RPB Manual.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.