OMRON K3HB-RNB-L2AT11 Manual K3HB-RNB-L2AT11 Communications Manual

Brand: OMRON
Product model: K3HB-RNB-L2AT11
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 1.86MB
Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element K3HB-RNB-L2AT11 Communications Manual.
Burnout Detector compatible with a,
wide-range of heater control methods K3HB-RNB-L2AT11
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance K3HB-RNB-L2AT11 Communications Manual.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Control supply voltage: 100 VAC; With voltage fluctuation compensation.
Operating current: 32 to 80 A.
Accurate Detection of Heater Element K3HB-RNB-L2AT11 Communications Manual.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated froom the start of operation K3HB-RNB-L2AT11 Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-RNB-L2AT11 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Rotating pulse meter
K3HB-RNB-A AC/DC24V
OMRON Rotating pulse meter K3HB-RNB-A AC/DC24V
Input type: NPN/ voltage pulse input type. E
OMRON
Voltage and current panel meter
K3HB-XVA-L2AT11 AC100-240
OMRON Voltage and current panel meter K3HB-XVA-L2AT11 AC100-240
Type of input: AC voltage input. Output type
OMRON
Rotating pulse meter
K3HB-RNB-A AC100-240
OMRON Rotating pulse meter K3HB-RNB-A AC100-240
Input type: NPN/ voltage pulse input type. E