Type of input: AC voltage input.
Output type: relay contact; 1c H; PASS, L: each 1c.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-HTA-1 User's Manual
K3HB-HTA-1
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
DepthInput type: NPN/ voltage pulse input type K3HB-HTA-1 User's Manual.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Communication: RS-485; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Digital rotating pulse meter with high speed measurement for 50kHz K3HB-HTA-1 User's Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of 50kHz high speed pulse.
Can rotate the encoder and a variety of ON/OFF pulse signal, up to 50Static type reverse electric relay K2FW type.
Ensure high accuracy digital UFR/OFR.
Constitute by the crystal oscillator plus digital IC,
Can achieve high accuracy of frequency detection (adjustment, detection accuracy of less than 0.1HZ).
50-60HZ share, can be adjusted arbitrarily in the range of 45-65HZ through the surface of the dial switch plate.
Because of the high speed detection, the low frequency relay can detect the system accident before the under voltage relay. Control supply voltage: 110/220 VAC; Without voltage fluctuation compensation.
Operating current: 1 to 2 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the buurned element even if one heater el,
ement among several heater elements has been burned out K3HB-HTA-1 Manual.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with booth single-phase and three-phase heaters K3HB-HTA-1 Manual.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.