OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON EJ1G-TC2A-QNH Manual EJ1G-TC2A-QNH User's Manual

OMRON EJ1G-TC2A-QNH Manual EJ1G-TC2A-QNH User's Manual

Brand: OMRON
Product model: EJ1G-TC2A-QNH
Name: Temperature Controller
Sort: User's Manual
File language: English
File size: 4.31MB
Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, -- EJ1G-TC2A-QNH User's Manual.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance EJ1G-TC2A-QNH Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks EJ1G-TC2A-QNH User's Manual.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors EJ1G-TC2A-QNH User's Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Terminal type: Exposed-lead Models.
Protective tubing diameter D: 3.2 dia.
Protective tubing length L: 35cm.
Lead wire type: Standard.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal EJ1G-TC2A-QNH Manual. Sensing method: Through-beam.
Connection method: Pre-wired (2 m).
Sensing distance: 25 mm.
No. of opti- cal axes: 2.
Model: NPN output.
Photoelectric Sensor with Grooved.
Design and Easy Settings . EJ1G-TC2A-QNH Manual.
Groove-type Sensor with groove width of 25 mm.
Models are available with one or two light axes.
Models are available with M8 pre-wired connectors.