Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 4 loops;
Temperature sensor inputs: Platinum ,
resistance thermometer input(JPt100, Pt100);
Control outputs: Open collector PNP outputs (pulses).
No. of unit numbers allocated: 2 CJ1W-ID262 PROGRAMMING MANUAL.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE
CJ1W-ID262
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output. Name: Three-tier Screw Terminal Block.
Specifications: Inputs/Outputs;
8 inputs/8 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection CJ1W-ID262 PROGRAMMING MANUAL.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site CJ1W-ID262 PROGRAMMING MANUAL.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. vModel: CPM2C-20CDR-D. CPU Unit: Units with 20 I/O points.
I/O terminal block.
Inputs: 12 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: relay.
Internal clock: --.4 platinum resistance thermometer inputsModel: C500-COV03.
C500 I / O Control Unit, I / O Interface For unitModel: C200H-OD501.
No. of outputs: 32 pts.
Specifications: 5VDC.Name: Repeater Unit.
Specifications: A sub-trunk line can be,
connected downstream,
(for trunk-branch line configuration),
or further branching is enabled downstream,
(for configurations with no wiring restrictions),
in the same way as for a Master Unit.
A Repeater Unit can be used to branch,
the trunk line and increase the,
number of connected Units,
as well as to extend the length of the,
communications line.
Standards: CE, U, U1, L, N.
Simple and Intelligent Bit Slaves,
with Industry-standard e-CON connectors.
Slave Units capable of 2-point bit-level distribution.
The I/O power supply is supplied from the communications,
power in the previously connected flat cable, and has a,
short-circuit detection function for protection CJ1W-ID262 Hardware Manual.
Industry-standard e-CON connectors.
Short-circuit protection safeguards the network,
from I/O short circuits CJ1W-ID262 Hardware Manual.
Simple communications connections,
with flat cable and connectors.
Bit-level distribution to support,
essentially any application.