Unit type: CS1 CPU Bus Unit.
Product name:FL-net Unit.
Specifications: Communications interface,
100BASE-TX; Communications functions,
With FL-net Ver. 2.0 specifications,
(OPCN-2) Data links and message service;
Max. Units mountable per CPU Unit,4.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0 C500-RM201 INSTRUCTION SHEET. 38A; 26V, --.
Standards: UC1, CE.
Connect to Multivendor Controller Networks
C500-RM201
This Unit allows you to connect to FL-net,
an open network based on Ethernet.
Multivendor FL-net networks can be built to,
combine CS series PLCs with CNC machines,
robots, and PLCs from other manufacturers. Product name: N@@-type CPU Units with 60 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 36; Outputs, 24;
Output type: Transistor (sourcing) C500-RM201 INSTRUCTION SHEET.
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): 0.30A.
Current consumption: 5 V, 0.31A; 24 V,0.02A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality C500-RM201 INSTRUCTION SHEET.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Unit type: CS1 Special I/O Units.
Product name: Analog Input Unit (100 mV).
Input points : 8 inputs.
Signal range: 0 to 100 mV, ±100 mV.
Conversion speed (resolution):
200ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.08A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spaace compared,
with previous systems C500-RM201 Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems C500-RM201 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.