Model: CPM2C-8ET1C. Units with relay outputs only.
1 Fujitsu connector.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sourcing transistor.CV500-RT SYSMAC BUS Remote I/O Slave Unit (wired) CV500-RT221.
Wire Type.Unit type: CS1 Basic I/O Units.
Product name: B7A Interface Unit.
Specifications: 16 inputs/outputs C200H-TC101 OPERATION MANUAL.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No
C200H-TC101
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No.
Words required: 1 input word and 1 output word.
Current consumption: 5V system, 0.09A;
26 V system, --.
Standards: UC1, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control C200H-TC101 OPERATION MANUAL. Number of inputs: 32 pts.
Input Voltage: 12 V DC.
Input Current: 4 mA.Expands G730 output capacity of G730 remote master ; adds 32 or 16 outputs, DIP switch selected.Supply voltage: 100 or 230 V AC (selectable), 50/60 Hz.
Operating voltage range: 85 to 265 V AC.
Output capacity: 5 V DC: 6 A 24 V DC: 0.5 A(30 W total, see note) C200H-TC101 OPERATION MANUAL. Unit type: CS1 Special I/O Units.
Product name: Isolated-type Resistance,
Thermometer Input Units (Ni508.4 Ω).
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: INi508.4.
Conversion speed (resolution):
100 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacce compared,
with previous systems C200H-TC101 Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems C200H-TC101 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.