Box protection class: metal, IP00.
Terminal size: M6.
Line diameter: 22 square mm.
Weight: 3.6kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line.
Try to be close to the transducer for connection. Function name: 3 phase 400V.
Power: 4 3G3MX2-A4110-ZV1 Quick Reference Guide. 0KW.
Rated output voltage: 3 phase, 380 ~ 480V (the output voltage can not exceed the input voltage)
3G3MX2-A4110-ZV1
Built in brake unit (brake resistance needs to be matched).
Weight: 2.1KG.
Dimension (w * h) 128mm *:140.
Outline dimension (deep):170.5mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function 3G3MX2-A4110-ZV1 Quick Reference Guide.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Specification: three phase 200V.
Power: 0.4KW.
Maximum output voltage: three phase input voltage.
Rated voltage, frequency: three-phase power supply 200 ~ 50/60Hz, 240V.
Cooling way: natural wind cooling 3G3MX2-A4110-ZV1 Quick Reference Guide.
Weight: 1.1kg.
Open loop vector control mode of low speed and high torque, rich control function and convenient distribution management network function,
Set in one of the inverter --3G3MZ.
3G3MZ series inverter for the application of frequency control and development.
Humanized design and advanced management technology, as well as OMRON a simple style of modeling, feature rich style,
Combined with the latest technical needs of users, so that it has a noble lineage and the most close to the market elements.
Covers the special features of the fan pump class, open loop vector function,
Built in noise filter and a variety of network bus,
3G3MZ will be your most economical and the most perfect choice. Function name: three phase 400V.
Power: 1.5KW.
Maximum output voltage: three phase 380 ~ 480VAC (corresponding input voltage).
Rated voltage, frequency: three-phase power supply 380 ~ 50/60Hz, 480V.
Cooling: forced cooling.
Weight: 1.2kg.
Simple but not simple, casual and not casual.
Homogenization of today, the quality of the subtle show.
Standard configuration has RS485 interface, Modbus bus communication function.
3HHz provides more than 150% torque output 3G3MX2-A4110-ZV1 Manual.
2-15kHz carrier frequency, can achieve mute driver.
Equipped with simple energy saving function.
Compact size and uniform, and can be installed close to the side by side.
Signal outpput function for controlling external brake action 3G3MX2-A4110-ZV1 Manual.
Software setting operation mode, no need to connect the control line can be used for speed control.