Brand: OMRON
Product model: K2CM-Q2MA
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 0.29MB
Input type: PNP input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Relay contact: H; PASS1c, L, each 1c.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table K2CM-Q2MA Communications Manual K2CM-Q2MA
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, the maximum measurable range from 10ms to 3200sType of input: AC current input K2CM-Q2MA Communications Manual.
Output type: linear; current; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K2CM-Q2MA Communications Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNet typeCategory: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Relay contact: H; PASS1c, L: each 1c.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torquue and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K2CM-Q2MA Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend K2CM-Q2MA Manual.
External event input can be applied to a variety of measurement and identification situations.
Related products
OMRON
Motor Protective Relay
K2CM-Q4M
OMRON Motor Protective Relay K2CM-Q4M
Time specification: Instantaneous type. Curre
OMRON
Motor Protective Relay
K2CM-Q2MAV
OMRON Motor Protective Relay K2CM-Q2MAV
Time specification: Instantaneous type. Curre
OMRON
Motor Protective Relay
K2CM-Q2HA
OMRON Motor Protective Relay K2CM-Q2HA
Time specification: Instantaneous type. Curre
OMRON
Motor Protective Relay
K2CM-Q1HA
OMRON Motor Protective Relay K2CM-Q1HA
Time specification: Instantaneous type. Curre