Isolation: Phototriac.
Zero cross function: No.
Indicator: No.
Rated output load: 10 A at 100 to 240 VAC.
Rated input voltage(See note 1, 2.): 5VDC, 12VDC, 24VDC.
Compact, Low-cost, SSR Switching 5 to 20 A.
Wide load voltage range: 75 to 264 VAC. Both 100-V and,
200-V loads can be handled with the same model GX-OD3228 PDF datasheet.
Dedicated, compact aluminum PCB and power elements used
GX-OD3228
Built-in varistor effectively absorbs external surges.
Quick-connect #110 input terminals and #250 output,
connections. (#187 input terminals and #250 output,
connections are available.).
“-US” models certified by UL, CSA, and IEC/EN (TÜV). Terminal (wire connection): Push-In Plus Terminal.
Applicable output load: DC load GX-OD3228 PDF datasheet.
Zero cross function: --.
Rated input voltage: DC 12V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals GX-OD3228 PDF datasheet.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Input terminals: M3 terminals.
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 1 output (Heater Burnout Detection,
SSR Short-circuit Failure Detection, Common).
Applicable load (See note.): 2 to 35 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures GX-OD3228 datasheet PDF catalog.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp termiinals (detachable), or compact slotted,
screw terminals (detachable) GX-OD3228 datasheet PDF catalog.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.