OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E5EC-TQX4DSM-060 Manual E5EC-TQX4DSM-060 INSTRUCTION Manual

OMRON E5EC-TQX4DSM-060 Manual E5EC-TQX4DSM-060 INSTRUCTION Manual

Brand: OMRON
Product model: E5EC-TQX4DSM-060
Name: digital controller
Sort: INSTRUCTION Manual
File language: English
File size: 1.02MB
Item: Advanced models, External-input models.
Functions: Remote setting, differential operation.
Model: NPN output.
Proximity Sensor with Separate.
Amplifier Enables Easily Making High.
precision Sensitivity Settings.
Wide variety of Sensor Heads to select according to the,
application. Flexible cables are used between Preamplifiers,
and Amplifier Units of the Sensor Heads E5EC-TQX4DSM-060 INSTRUCTION Manual E5EC-TQX4DSM-060
High resistance to changes in ambient temperature.
Temperature characteristics of 0.08%/°C (for 5.4-dia. models).
Make simple and reliable detection settings with micron,
level precision using the teaching function.
Check the sensing excess gain level on the digital display.
Support for high-precision positioning and screening with,
fine positioning to maximize variations E5EC-TQX4DSM-060 INSTRUCTION Manual.
The E2C-EDA0 supports an EtherCAT Sensor,
Communications Unit or CompoNet Sensor,
Communications Unit. The small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc E5EC-TQX4DSM-060 INSTRUCTION Manual. .
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CS-Thermo (sold separately). Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard.
Auxiliary output points: -.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Furthher performance improvement E5EC-TQX4DSM-060 Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5EC-TQX4DSM-060 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
Digital temperature controller program
E5EC-TCX4DSM-060
OMRON Digital temperature controller program E5EC-TCX4DSM-060
Size: 48 x 96mm. Control output 1: current.
OMRON
Digital temperature controller program
E5EC-TQX4DSM-068
OMRON Digital temperature controller program E5EC-TQX4DSM-068
Size: 48 x 96mm. Control output 1: voltage.
OMRON
Digital temperature controller program
E5EC-TQX4DSM-080
OMRON Digital temperature controller program E5EC-TQX4DSM-080
Size: 48 x 96mm. Control output 1: voltage.
OMRON
Digital temperature controller program
E5EC-TQX4ASM-070
OMRON Digital temperature controller program E5EC-TQX4ASM-070
Size: 48 x 96mm. Control output 1: voltage.