OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E3Z-G61-11B Manual E3Z-G61-11B INSTRUCTION sheet

OMRON E3Z-G61-11B Manual E3Z-G61-11B INSTRUCTION sheet

Brand: OMRON
Product model: E3Z-G61-11B
Name: photoelectric sensors
Sort: INSTRUCTION sheet
File language: English
File size: 0.80MB
Control output 1: voltage output.
Auxiliary output: 2 points.
Communication mode: RS-485.
Heater break: 1.
Event input: -.
Power supply voltage: 100 ~ 240VAC.
Resistance to environmental performance of the industry leader.
Sulfide gas, dust, condensation of the corresponding.
Environment specific temperature controller E3Z-G61-11B INSTRUCTION sheet.
Temperature control performance outstanding E3Z-G61-11B
High contrast display screen.
Set simple, easy to operate. Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: built-in SSR output.
Control output 2: built-in SSR output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater E3Z-G61-11B INSTRUCTION sheet.
Event entry point: 4.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved E3Z-G61-11B INSTRUCTION sheet.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 4.8 dia.
Protective tubing length L: 50 cm.
Lead wire type: Standard.
Lead wire length M: 8m.
A Wide Variety of High-precision.
Temperatuure Sensors E3Z-G61-11B Manual.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E3Z-G61-11B Manual.