OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E3S-R16 Manual E3S-R16 INSTRUCTION sheet

OMRON E3S-R16 Manual E3S-R16 INSTRUCTION sheet

Brand: OMRON
Product model: E3S-R16
Name: photoelectric sensors
Sort: INSTRUCTION sheet
File language: English
File size: 10.23MB
Name: Basic Unit (temperature control) *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 4.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive) *2.
Control outputs 3 and 4: Voltage output: 2 points (for SSR drive) *2.
Auxiliary output: None.
Functions: burnout Heater alarm, None; Event inputs, None E3S-R16 INSTRUCTION sheet.
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485 E3S-R16
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: M3 terminal.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices E3S-R16 INSTRUCTION sheet.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements E3S-R16 INSTRUCTION sheet.
Connect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculate the PID constants with the step,
response method.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit. Size: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: 2 points.
Remote SP input: -.
Transfer output: have.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a varriety of applications E3S-R16 Manual.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermmo (sold separately) E3S-R16 Manual.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
Related products
OMRON
PCB Sensors
E3S-LS3NWT
OMRON PCB Sensors E3S-LS3NWT
Sensing method: Convergent reflective. Conn
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AR31
OMRON Built-in Amplifier Photoelectric Sensor E3S-AR31
Sensing method: Retro-reflective Sensors. Ap
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AD87
OMRON Built-in Amplifier Photoelectric Sensor E3S-AD87
Sensing method: Diffuse-reflective Sensors.
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AD31
OMRON Built-in Amplifier Photoelectric Sensor E3S-AD31
Sensing method: Diffuse-reflective Sensors.