OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON DRT2-OD16-NH Manual DRT2-OD16-NH INSTRUCTION Manual

OMRON DRT2-OD16-NH Manual DRT2-OD16-NH INSTRUCTION Manual

Brand: OMRON
Product model: DRT2-OD16-NH
Name: remote i/o terminal
Sort: INSTRUCTION Manual
File language: English
File size: 0.36MB
Lock method: Solenoid lock.
Conduit size: G1/2.
Voltage for solenoid: 24 VDC.
With LED indicator 1NC/1NO+ 1NC (Slow-action).
Release Protective Cover Locks Using.
Controller Signals or Pushbutton.
Switches after the Cutting Tool Stops.
Moving Due to Inertia.
A mechanical lock is applied automatically when the Operation DRT2-OD16-NH INSTRUCTION Manual.
Key is inserted. A high level of safety is achieved using a,
mechanism where the lock is only released when voltage is,
applied to the solenoid DRT2-OD16-NH
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL, CSA and CCC standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened DRT2-OD16-NH INSTRUCTION Manual.
Direct opening mechanism that is EN-certified is indicated by,
on the Switch.
Auxiliary release key ensures easy maintenance and unlocks the,
door in the case of a power failure.
Tough aluminum die-cast body incorporating a switch box with,
degree of protection satisfying IP67, UL, and CSA TYPE6P, 13.
Equipped with a horizontal and vertical conduit opening.
Models incorporating easy-to-see indicators for monitoring and,
those using an adjustable Operation Key for a swinging door are available DRT2-OD16-NH INSTRUCTION Manual.
The mounting direction of the head can be changed,
to allow the Operation Key to be inserted from four directions. Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Plastic rod.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models DRT2-OD16-NH Manual.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
connfirmation of operation DRT2-OD16-NH Manual.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)