C200H Accessory Programming Console Adapter C200H-BP002.Product name: N@@-type CPU Units with 20 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 12; Outputs, 8;
Output type: Transistor (sinking).
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): -- CP1L-M60DT1-D REFERENCE MANUAL.
Current consumption: 5 V, 0.23A; 24 V,0.02A.
Standards: UC1, N, L, CE
CP1L-M60DT1-D
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection CP1L-M60DT1-D REFERENCE MANUAL. Model : C500-II101.
Necessary to connect Expansion I/O Backplane.C500-GP Special I/O Unit GPIB Interface Unit C500-GPI01.CV500-BS CPU Bus Unit BASIC Unit CV500-BSC61.
RS-232C: 1 port.
GP-IB: 1 port.
(w/EEPROM).C200H-COVOutput method: Transistor sourcing.
Inputs: 12.
Outputs: 8.Number of inputs: 8 pts.
Input Voltage: 200 to 240VAC.
Input Current: 6 mA.Unit type: CS1 Special I/O Units CP1L-M60DT1-D REFERENCE MANUAL.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
0 to 10 V, ±10 V, 0 to 5 V, ±5 V,
1 to 5 V, 0 to 1.25 V, ±1.25 V.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previouus systems CP1L-M60DT1-D Communications Commands Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1L-M60DT1-D Communications Commands Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.