Model: C200HW-ME64K.
Capacity: 64K words.Unit type: CS1 Basic I/O Units.
Product name: Relay Output Units.
Specifications: 12 to 24 VDC,
0.1 A 96 outputs; Sinking.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No CJ1W-DA042V Instruction Manual
CJ1W-DA042V
Words required: 6 words.
Current consumption: 5V system, 0.48A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Unit type: CJ1 Basic I/O Units.
name: B7A Interface Units.
Specifications: I/O points, 64 outputs;
External connection, Removable terminal block CJ1W-DA042V Instruction Manual.
No. of words allocated: 4 words.
Current consumption: 5V, 0.07A; 24V, --.
Standards: UC1, CE.
It transmits 16 points of I/O signals per,
word with a pair of cables.
Easy and minimized wiring effort,
The B7A Interface Unit and B7A Link Terminal,
can be used in the same way as a standard,
Basic I/O Unit and I/O Terminal without,
any need to worry about communications CJ1W-DA042V Instruction Manual.
This characteristic reduces the wiring,
when using more than one relatively remote,
sensor or actuator.
Output type: Transistor sinking.
Inputs points: 12 points.
Outputs points: 8 points.No. of I/O slots: 11 slots.Connects Power Supply Adapter and SYSMAC NET Link Unit.
For 1 Unit.Connecting I/O control module and interface module.
Cable length: 0.3 m.C500-IM I/O Unit INPUT MODULE 32POINT 24VAC/DC C500-IM212(3G2A5-IM212).
AC/DC12-24V 10mA。I/O Slave Unit.
Number of words: 64Model: C200H-ID111.
No. of points: 64 pts.
Specifications: 12VDC.
Weight: 250g max.Unit type: CS1 CPU Bus Unit.
Product name:Ethernet Units.
Specifications: Communi cations cable,
100BASE TX Cable; Communications functions,
FINS communications service(TCP/IP and UDP/IP),
FTP server function, socket service,
mail send service, mail reception,
(remote command reception),
auto-adjustment of PLC''s internal clock,
and server host name speccification;
Duplexing, Not supported;
Units per CPU Unit, 4 Units CJ1W-DA042V Manual.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.38A; 26V, --.
Standards: UC1, N, L, CE.
Organically Connect the Production,
Site and Managemment CJ1W-DA042V Manual.
Select the required communications,
services according to application needs,
to flexibly integrate PLCs with an,
Ethernet information network.