Actuator: Roller lever R38.
Item: Hermetic seal, Molded terminals, -141 models; High-sensitivity.
Pretravel (PT): 10°.
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches.
Standard-feature gold-clad crossbar contacts provide high reliability
EE-SX4015A-P5
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on approved models. Amplifier Unit.
Separate Amplifier Sensor with.
Sensitivity Adjustment.
Compact design with smaller Sensor Head.
Heat-resistance model available for application between.
-10 and 200°C. Contact type: Standard load (250 VAC, 2 A; 125 VDC 0.4 A).
Operation: Alternate operation (Self-holding).
Output: DPDT.
Lighting: LED, 24 VDC.
Operation Unit color symbol: Enter the desired color symbol for the,
Pushbutton in @@. R (Red); Y (Yellow); G (Green); A (Blue); W (White).
Pushbutton Switch Series with.
Square 40-mm Body.
Combines miniature design with distinct but soft sense of operation.
Easy panel mounting from the front and simple lamp replacement.
without tools. Detection mode: diffuse reflection type.
Connection: socket type (M12).
Detection range: red light 100mm.
Output mode: PNP output. Case color: Black.
Control output: Relay output.
Control mode *1: Standard.
No. of auxiliary outputs: --.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-RTC;
Resistance thermometer input, E5GN-RP.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
EE-SX4015A-P5 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=EE-SX4015A-P5&select=5