Rated voltage: 230 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2100 r/min; 60 Hz, 2200 r/min.
Maximum flow rate: 50 Hz, 2.0 m3/min; 60 Hz, 2.1 m3/min.
Maximum static pressure: 50 Hz, 47 Pa; 60 Hz, 44 Pa.
Noise: 50 Hz, 45 dB; 60 Hz, 46 dB.
Weight: Approx. 2220 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting
E6HZ-CWZ1X 1500P/R 2M
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. Output: SPDT.
Lighting: Non-lighted.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. When the power supply capacity exceeds the power supply capacity of the inverter or the need to improve the power factor, it is required to connect the AC reactor.
Please according to the maximum capacity of heavy load and light load rated conditions suitable for motor to select option. Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Auxiliary outputs: 1.
Control output 1: Current output.
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
E6HZ-CWZ1X 1500P/R 2M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E6HZ-CWZ1X 1500P/R 2M&select=5