Appearance: Round/Half-guard type LED voltage-reduction lighting,
(with Voltage Reduction Unit) A22L-H.
Output: SPST-NO.
Lighting: LED.
Operating voltage: 100 VAC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit
E5CN-HTV2MD-500 AC/DC24
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Type: Standard Models.
Terminals: Plug-in.
Contact form: DPDT.
Internal connections (See note 3.): Standard.
With mechanical indicator and lockable test button.
Coil ratings: AC/DC.
New Super MK Relays.
Models with Latching Lever Added to the Series.
Same mounting and internal wiring as the previous Super.
MK Relays.
Built-in mechanical indicator enables checking contact operation.
Two modes can be used to check circuits for models with latching lever.
Nameplate provided on models with latching lever.
All materials are RoHS compliant.
UL and IEC (TÜV) certification. Isolation: Phototriac coupler.
Zero cross function: Yes.
Indicator: Yes.
Rated output load: 40 A at 24 to 240 VAC.
Rated input voltage: 5 to 24 VDC.
Extremely Thin Relays Integrated with Heat Sinks.
Downsizing achieved through optimum design of heat sink.
Mounting possible via screws or via DIN track.
Close mounting possible for linking terminals.
(Except for G3PA-260B-VD and G3PA-450B-VD-2.)
Applicable with 3-phase loads.
Replaceable power element cartridges.
Comply with VDE 0160 (finger protection),
with a dielectric strength of 4,000 V between input and load.
Certified by UL, CSA, and VDE (reinforced insulation). Size: 96 × 96 mm.
Control type: Basic control (1 loop).
Control mode: Standard control Heating and cooling control.
Outputs(control/transfer): 4 (pulse + pulse/current + 2 current).
Optional functions: Auxiliary outputs (SUB), 10 (Seenote 1.);
Event inputs, 10; Serial communications, RS-485.
A new High-speed, High-precision Digital.
Controller that is Programmable!
Create up to 32 programs with up to 256 segments total.
Coordinated operation for up to four channels with one Digital Controller.
0.01°C High resolution for Pt input.
High-speed sampling at 50 ms.
Settings easily made from a computer using the CX-Thermo.
RoHS compliance for world-wide application.
E5CN-HTV2MD-500 AC/DC24 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E5CN-HTV2MD-500 AC/DC24&select=5