Element type: J (IC).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 10 dia.
Protective tubing length L: 35 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal
E2E-X5ME15-Z 5M No. of poles: 4.
Suitable cable dia: 7 mm dia. model (6 to 7 mm dia.).
Suitable core size: 0.18 to 0.75mm.
Suitable Sheath material: PVC, PE, PUR.
Straight connectors (for DC).
Minimum order: 50.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Description: OS32C with back location cable entry.
Max. Operating Range (Safety Zone): 3m.
Remarks: CD-ROM (Configuration tool) OS supported: Windows 2000,
Windows XP (32-bit version, Service Pack 3 or later),
Windows Vista (32-bit version), Windows 7 (32-bit version/64-bit version),
For configuration tool version, refer to page 23.
Compact (104.5 mm), lightweight (1.3 kg),
and easy-to-install Safety Laser Scanner.
Provides a safety circuit of PLd/Safety Category 3 (ISO13849-1) without a,
dedicated controller.
Type 3 Safety Laser Scanner complies with IEC61496-1/-3.
70 sets of safety zone and warning zone combinations are available,
supporting complicated changes in working environments.
A safety radius up to 4 m and warning zone(s) radius up to 15 m can be set.
The minimum object resolution can be changed to 30, 40, 50 or 70 mm.
The response time is configurable from 80 ms to a maximum of 680 ms.
Reference Boundary Monitoring function prevents unauthorized changes in,
the scanner position.
Minimal down time, sensor block can be replaced without the need to reprogram.
E2E-X5ME15-Z 5M Operation manual / Instructions / Catalog download link: